CIC-D120 is a high-stability ion chromatograph with upgrade circuit . It can be compatible with external equipment such as amperometric detector, UV detector, ultraviolet-post-column derivatization device and so on. Using Shenghan leading IC column technology, the separation of anion, cation, cyanide, iodide, sugar and small molecular organic acids can be realized. It is widely used in the fields of environment, disease control, food, chemical industry, electronics, mining and metallurgy.
Technology Advantage
1.Temperature-control bipolar conductivity detector(CN 202033335U)
2.Greater detection range and better accuracy of analysis;
3.Built-in circulating 3D constant temperature technology(CN 204259917U)
4.Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data;
5.The world's leading full-range series of ion chromatographic columns(CN 105126936A,CN 104788603A)
6.High efficiency, large capacity ,satisfying the detection of various ion;
7.Self-regenerating electrolytic micro-membrane suppressor(CN 102735792A)
8.High pressure resistance, small dead volume and highly responsive to signals;
9.Observatory intelligent workstation
10.Integrated control, compatibility for a variety of instruments, customized images.
Technical parameters
Ion Chromatographic Pump | Type | High-pressure and low-pulse double plunger tandem advection pump | ||
Maximum Pressure | 35MPa | |||
Pressure Display Accuracy | ≤0.1MPa | |||
Flow Stability | (0.2-0.5)mL/min≤3%; (0.5-1.0)mL/min≤2%; >1.0mL/min≤2%; | |||
Allowable Deviation of Flow | (0.2-0.5)mL/min , ±5%; (0.5-1.0)mL/min, ±3%; >1.0mL/min, ±2%; | |||
Flow Range | 0.001~9.999mL/min | |||
Pressure Pulse | ≤5% | |||
Numerical-control and Electromagnetic Sample Injector | Maximum Pressure | 35MPa | ||
Contact Material of the Rotor | PEEK | |||
Control Mode | By stepper motor | |||
Power Supply | 24V (DC) | |||
Digital and Temperature control Detection System | Conductivity detector | Type | Temperature-control and bipolar conductivity detector | |
Detection Mode | Bipolar conductivity detection | |||
Cell Volume | ≤0.8uL | |||
Detection Range | 0~45000μS/cm | |||
Detection Resolution | ≤0.0020nS/cm | |||
Output Voltage | -6000~+6000 mV (adjustable) | |||
Baseline Noise | ≤0.05% FS | |||
Baseline Drift | ≤3% FS/30min | |||
Operating Temperature Range | Room temperature +5 ℃ ~60 ℃ | |||
Controlling Temperature Accuracy | ±0.01 ℃ | |||
Maximum Pressure | 10.0 MPa | |||
Linear Range | ≥103 | |||
Instrument Linearity | ≥0.999 | |||
Quantitative Repeatability | ≤1.0% | |||
Qualitative Repeatability | ≤1.0% | |||
Minimum Detectable Concentration | Cl-≤0.0005ug/mL; Li+≤0.001 ug/mL; BrO3-≤0.001 ug/mL; | |||
Flow System | Plastic Flow Path | Made of PEEK materials | ||
Six-way Valve
| PEEK material, pressure 5000psi;Independent automatic collecting and flow function. | |||
Power Supply | 150W | |||
External Size(L*W*H*) | 350*470*510 | |||
Net Weight(KGS) | 26 | |||
Gross Weight(KGS) | 32 |