Dragon Series Online UPS 1-3kVA (1in/1out Tower Mount)
Features:
1, DSP technology: The advanced DSP digital control technology enables UPS more stable performance.
2, Environment friendly: This UPS is eco-designed and manufactured to meet the pollution control requirement of Electronic Products, which means it will cause no harm to environment and human beings in normal usage.
3, Active input power factor correction (PFC): Digital control of the DFC enables the UPS to keep input power factor above 0.99 to prevent possible electric grid pollution and meanwhile mostly save the cost.
4. Wide range of input voltage and frequency: We intentionally widen the range of input factors to make sure the UPS can apply to various environment, which will effectively sustain the battery charging even in unstable power environment so that the service life of the UPS could be obviously prolonged.
5. Zero power switch delay: When the utility power fails, UPS will automatically switch from AC mode to battery mode with no delay, which ensure stable power supply of operating system.
6. Adaptive load management: This technology allows the UPS to be set up at a fixed 50Hz or 60Hz output, while it also can intelligently monitor power usage and automatically shed and reconnect loads in order to prevent generator overload.
7. Sufficient expansion slots: The pre-allocated smart slots enable flexibility in choice of USB cards, AS400 cards, CMC monitoring cards, SNMP cards, RS485 cards and EMD environment monitoring cards.
8. Support the generator: The wide range of input voltage and frequency can effectively separate the harmful electric wave produces by the generator and provide safe and reliable power supply.
9, N+X parallel connection(6-20KVA)
10,Insulation transformer (optional)
Model | 1K | 1KL | 2K | 2KL | 3K | 3KL |
Rating | 1kVA/800W | 2kVA/1600W | 3kVA/2400W | |||
Input | ||||||
Input system | Single phase & earth ground | |||||
Voltage range | (90±5)VAC~ (300±5)VAC | |||||
Power factor | ≥0.99 | |||||
Voltage range of bypass | (80±5)VAC~ (286±5)VAC (default: 80VAC~264VAC Could be adjusted by software) | |||||
Output | ||||||
Output system | Single phase & earth ground | |||||
Rated voltage | 220VAC | |||||
Power factor | 0.8 | |||||
Voltage precision | ±2% | |||||
Normal mode frequency | The output frequency synchronizes with the input frequency when the input frequency is in the range of 46 Hz~ 54 Hz. | |||||
| The output frequency is 50Hz when the input frequency is not in the range of 46 Hz~ 54 Hz. | |||||
Battery mode frequency | Can be set as 60Hz. | |||||
Inverter overload capacity (Utility power, 25℃) | 105% ± 5% < Load ≤ 125% ± 5% 50s transfer to bypass; 125% ± 5% < Load <150% ± 5% 25s transfer to bypass; Load > 150% ± 5%, 300ms transfer to bypass | |||||
Transfer time | 0ms (Normal mode←→ Battery mode); <4ms (Normal mode←→Bypass mode) | |||||
Crest factor | 3:01 | |||||
Battery | ||||||
Batteries voltage | 36VDC | 72VDC | 96VDC | |||
Battery quantity | 3pcs | None | 6pcs | None | 8pcs | None |
Battery Type | Sealed maintenance-free lead –acid battery of battery voltage 12V7AH | |||||
Backup Time (25℃) | Full load≥5min (Standard) | |||||
Charge current | 1A | 6.5A | 1A | 5.5A | 1A | 5.5A |
Panel Display | ||||||
LCD | UPS status, input/output voltage and frequency, battery voltage, capacity, load temperature, history records, adjust voltage | |||||
Communication Port | 9Pin D type connector (RS232), or intelligent slot (Optional), or USB port | |||||
Working Environment | ||||||
OperatingTemperature | 0ºC~ 40 ºC | |||||
Relative Humidity | 0 ~ 95% ( Non-condensing ) | |||||
Elevation | 1000 m | |||||
Physics Characteristic | ||||||
Net Weight ( Kg ) | 11.5 | 6 | 22.5 | 10 | 27.5 | 11 |
Dimension: (W*D*H) mm | 350*144*230 | 350*144*230 | 425*190*328 | 425*190*328 | 425*190*328 | 425*190*328 |
Note1: Output voltage can be set: 200V/208V/220V/230V/240V.
(L): Long backup model