Parameters | Unite | Datas | Specification | ||
Furnace body | rated capacity | t | 0.5 | iron steel copper liquid | |
max capacity | t | 0.6 | iron steel copper liquid | ||
working temperature | ºC | 0-1800 | / | ||
highest temperature | ºC | 1800 | / | ||
Transformer | transformer capacity | KVA | 630 | / | |
no-load voltage | V | 540 | three-phase | ||
Transformer | grid-side voltage | V | 10 | three-phase | |
KGPS power supply | Power factor | 0.9 | 0.9 | / | |
KGPS IF power supply | rated power | KW | 350 | / | |
rated input current | A | 560 | / | ||
rated input voltage | V | 380 | / | ||
IF voltage | V | 750 | / | ||
startup success rate | % | 100 | / | ||
rated working frequency | KHZ | 0.5-1 | / | ||
working noise | db | ≤75 | / | ||
Comprehensive parameters | melting rate | T/h | 0.5 | melting rate is varied from different metal. | |
power consumption | KW.h/T | 600 | / | ||
Water cooling system | water consumption | T/h | 35 | / |
Model (Furnace capacity) | Input power 50Hz | ||||||
(Furnace capacity) | Rated Power | Rated Voltage | Rated Current | Transformer capacity | |||
GW-0.05T | 50 KW | 380V | 80A | / | |||
GW-0.1T | 100 KW | 380V | 160A | / | |||
GW-0.15T | 160 KW | 380V | 256A | / | |||
GW-0.2T | 160 KW | 380V | 256A | / | |||
GW-0.25T | 200 KW | 380V | 320A | / | |||
GW-0.35T | 250 KW | 380V | 400A | 315KVA | |||
GW-0.5T | 350 KW | 380V | 560A | 400KVA | |||
GW-0.75T | 500 KW | 380V | 800A | 630KVA | |||
GW-1T | 750 KW | 380V | 1200A | 800KVA | |||
GW-1.5T | 1000 KW | 380V/750V | 1600A/770A | 1250KVA | |||
GW-2T | 1400 KW | 750V | 1078A/539A*2 | 1600KVA | |||
GW-3T | 2000KW | 750V | 770A*2 | 2500KVA | |||
GW-5T | 3000KW | 950V/1000V | 912A*2/866A*2 | 4000KNA | |||
GW-10T | 5000KW | 1000V | 1443A*2 | 6300KVA | |||
GW-15T | 8000KW | 1000V | 1155*4 | 10000KVA | |||
GW-20T | 10000KW | 1000V | 1443*4 | 12600KVA | |||
GW-30T | 15000KW | 1000V | 2165*4 | 16000KVA |