Enquiries
Message
Home > Products > Other
16 channel thermocouple data logger
  • 16 channel thermocouple data logger

16 channel thermocouple data logger

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Shanghai, China
Brand Name:
TESHI
Model Number:
TSHOR
datalogger:
16 channel thermocouple data logger
Input signal:
Universal input
Output signal:
4-20ma
Feed output:
DC24V
Alarm output:
YES
Measurement accuracy:
0.2%FS±1d
Sampling period:
1s
Environment temperature:
Environment temperature: -10 ~ 50°C;
Working power supply:
AC 85 ~ 264 V (power supply of the switches), 50/60 Hz
power consumption:
≤20 W.
Packaging & Delivery
Product Description

Universal input of color paperless recorder (capable of inputting by means of configuration: standard voltage, standard current, thermocouple, thermal resistance, millivolt, etc.). It can be equipped with 18-channel alarm output or 12-channel analog transmitting output, RS232/485 communication interface, Ethernet interface, mini-printer interface, USB interface and SD card socket; can provide sensor distribution; is equipped with powerful display function, real-time curve display, historical curve retrospection, bar graph display, alarm list display, etc. The meter is of high cost effectiveness due to its humanized design, perfect function, reliable hardware quality and exquisite craft.


Input signal:

Current: 0~20mA, 0~10mA, 4~20mA, 0~10mA square root, 4~20mA square root

Voltage: 0~5V, 1~5V, 0~10V, ±5V, 0~5V square root, 1~5V square root, 0~20 mV, 0~100mV, ±20mV, ±100mV

Thermal resistance: Pt100, Cu50, Cu53, Cu100, BA1, BA2

Linear resistance: 0~400Ω

Thermocouple: B, S, K, E, T, J, R, N, F2, Wre3-25, Wre5-26


Output signal:


Analog output: 4~20mA (load resistance ≤380Ω), 0~20mA (load resistance ≤380Ω), 0~10mA (load resistance ≤760Ω), 1~5V (load resistance ≥250KΩ), 0~5V (load resistance ≥250KΩ), 0~10V (load resistance ≥500KΩ)


Alarm output: normally open relay contact output, where the contact capacity is 1 A/250 VAC (resistive load)
(! Note: Please do not carry load directly in case the load exceeds the contact capacity of relay.)


Feed output: DC24 V ± 1, load current ≤ 250 mA


Communication output: RS485/RS232 communication interface, 1,200 ~ 57,600 bps baud rate (able to be set); standard MODBUS RTU communication protocol is adopted; the communication distance of RS-485 can be as long as 1 kilometer; the communication distance of RS-232 can be as long as 15 m; EtherNet communication interface is adopted, where the communication speed is 10 M.

Product Name
pressure data logger
Material
stainless steel
Measurement accuracy
0.2%FS±1d
Sampling period
1 s
Setting mode
The button is set in the form of panel soft touch; setting values of parameters are locked with passwords and will be saved permanently in case of outage.
Display method
7-inch 800 * 480 dot-matrix widescreen TFT high brightness color graphics and LCD display;

LED backlight; with clear pictures and wide visual angle.

Display contents can be composed of characters, figures, conditional curves, bar graphs, etc.; through panel button, page turning, forward and backward search of historical data, time scale change of curves, etc. can be realized.
Data backup
Data backup and conversion storage of USB flash disk and SD card are support, where the maximum capacity is 8 GB; FAT and FAT32 formats are supported.
Storage capacity
The capacity of the internal Flash memory is 64 M Byte
Recording interval
Nine options including 1, 2, 4, 6, 15, 30, 60, 120 and 140 s can be selected
Storage length 
24 days (1 s interval) – 5825 days (240 s interval)
Working power supply
AC 85 ~ 264 V (power supply of the switches), 50/60 Hz;

DC12 ~ 36 V (power supply of the switches)
power consumption
≤20 W
Environment condition
Environment temperature: -10 ~ 50°C;

Relative humidity: 10 ~ 90% RH (without condensation of moisture);

Avoidance of contact of high corrosive gas.

(! Note: If the field environment is poor, special instruction should be given when ordering.)
Products Show
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier

This product information:


Input: 12 channels (universal input)

RS485 communication


Power range: AC85-265V (50/60Hz)

Ethernet communication

The above price is the price of this specification, please contact customer service if you need more changes.

product model
16 channel thermocouple data logger from China supplier
16 channel thermocouple data logger from China supplier
FAQ

Q: Are you trading company or manufacturer ?

A: We are factory.

Q: How long is your delivery time?

A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?

A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shippment.
If you have another question, pls feel free to contact us as below:

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher