15KVA Off Grid 3 Phase Inverter DC48V to AC220V/380V/400V
15KVA Off Grid 3 Phase Inverter DC48V to AC220V/380V/400V
15KVA Off Grid 3 Phase Inverter DC48V to AC220V/380V/400V
Type |
NB48-15KSZ |
NB96-15KSZ |
NB120-15KSZ |
NB240-15KSZ |
|
DC input |
Input rated voltage |
48 VDC |
96 VDC |
120 VDC |
240 VDC |
Input rated current |
347 A |
174 A |
139 A |
69 A |
|
Input DC voltage range |
40-62VDC |
80-124 VDC |
100-155 VDC |
200-310 VDC |
|
AC input (AC Bypass) |
Allow input voltage range |
220 VAC / 380 VAC / 400 VAC ± 15% VAC |
|||
Input rated current |
39A / 23A / 22A |
||||
Bypass transfer time |
≤100 ms (≤4ms can be customized) |
||||
AC output |
Rated capacity |
15KVA |
|||
Output rated power |
12KW |
||||
Output rated voltage and frequency |
220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz |
||||
Output rated current |
39A / 23A / 22A |
||||
Output voltage accuracy |
220 VAC / 380 VAC / 400 VAC ± 1% |
||||
Output frequency accuracy |
50Hz / 60Hz ± 0.05% |
||||
Waveform distortion (THD) |
≤3% |
||||
Dynamic response time |
2ms |
||||
Power factor (PF) |
0.8 |
||||
Overload capacity |
110%,3 minutes,150%, 5 seconds |
||||
Crest factor (CF) |
1.4 |
||||
Inverter efficiency |
>90% |
||||
Working Environment |
Dielectric strength |
1500VAC,1minute |
|||
Noise (1m) |
≤50dB |
||||
Ambient temperature |
-10℃~+50℃ |
||||
Humidity |
0~90%, No condensation |
||||
Altitude |
<2000m Higher than 2000m, rated power should be reduced |
||||
Production function |
Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection |
||||
Pure Sine Wave |
Yes |
||||
Equipped with copper transformer |
Yes |
||||
Solar Charger |
Optional |
||||
AC Charger |
Optional |
||||
Generator Port |
Optional |
||||
Size |
520*1160*1350 mm |
||||
Weight |
280 kgs |
15KVA Off Grid 3 Phase Inverter DC48V to AC220V/380V/400V
Service guarantee
As our corporate users, you enjoy the following service:
(1) The machine warranty for free in 2 year;
(2) Technical support;
(3) Within 24 hours for respond after receiving notification;
(4) Cost maintenance forever.
When you confirm the failure of equipment, please promptly contact us and provide the equipment model and complete description of the problem.
However, any of the following situation happened, are not included in the warranty:
(1) Non-permitted by the company, went ahead with repair and damage;
(2) Install or modify arbitrarily;
(3) Incorrect operation or use;
(4) Do not depending on the manual to do cleaning or maintenance;
(5) Abnormal environment condition exceed the specifications, result in damage;
(6) The deliberate destruction of man-made;
(7) Irresistible natural disasters.
15KVA Off Grid 3 Phase Inverter DC48V to AC220V/380V/400V
15KVA Off Grid 3 Phase Inverter DC48V to AC220V/380V/400V
15KVA Off Grid 3 Phase Inverter DC48V to AC220V/380V/400V