150KVA/120KW 380Vdc off grid solar power inverter three phase 400Vac/380Vac
Type |
NB380-150KSZ |
NB480-150KSZ |
|
DC input |
Input rated voltage |
380 VDC |
480 VDC |
Input rated current |
395 A |
315 A |
|
Input DC voltage range |
300-490 VDC |
350-600 VDC |
|
AC input (AC Bypass) |
Allow input voltage range |
220 VAC / 380 VAC / 400 VAC ± 15% VAC |
|
Input rated current |
415A / 225A / 217.5A |
||
Bypass transfer time |
≤4 ms |
||
AC output |
Rated capacity |
150KVA |
|
Output rated power |
120KW |
||
Output rated voltage and frequency |
220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz |
||
Output rated current |
415A / 225A / 217.5A |
||
Output voltage accuracy |
220 VAC / 380 VAC / 400 VAC ± 2% |
||
Output frequency accuracy |
50Hz / 60Hz ±0.05% |
||
Waveform distortion (THD). |
≤3% |
||
Dynamic response time |
5% |
||
Power factor (PF) |
0.8 |
||
Overload capacity |
120%,3 minutes,150%,10 second |
||
Crest factor (CF) |
3:1 |
||
Inverter efficiency |
90% |
||
Working Environment |
Dielectric strength |
1500VAC,1minute |
|
Noise (1m) |
≤50dB |
||
Ambient temperature |
-10℃~+50℃ |
||
Humidity |
0~90%,No condensation |
||
Altitude |
≤5000 m |
||
Pure Sine Wave |
Yes |
||
Equipped with copper transformer |
Yes |
||
If solar charger available |
Yes |
||
Production function |
Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection |
||
Size(mm) |
1600*1000*2000mm |
||
Weight(kg) |
1400kg |
Display
No. |
Name |
Explain |
Function |
1 |
Start / stop button |
|
Press this key to enter the running state, bounce the key to enter the standby mode. |
2 |
Power / power factor conversion button |
|
Press the button to switch the display the actual load power and power factor values |
3 |
Power factor indicator |
|
When the light, the window 9 display load power factor |
4 |
Power indicator |
|
When the light, the window 9 display the power unit of load is watts. |
5 |
Kilowatts indicator |
|
When the light,, the power window displays the load power in kilowatts |
6 |
Power / power factor display window |
LED display |
Shows the actual load power or power factor in the running state |
7 |
Current display window |
LED display |
Show the actual output current value in the running state. |
8 |
Voltage display window |
LED display |
Show the actual output voltage value in the running. Voltage display range: 260V |
9 |
Frequency display window |
LED display |
Actual output frequency value displayed in the running state. |
Inverter power supply system drawing
Service guarantee
As our corporate users, you enjoy the following service:
(1) The machine warranty for free in 1 year;
(2) Technical support;
(3) Within 24 hours for respond after receiving notification;
(4) Cost maintenance forever.
When you confirm the failure of equipment, please promptly contact us and provide the equipment model and complete description of the problem.
However, any of the following situation happened, are not included in the warranty:
(1) Non-permitted by the company, went ahead with repair and damage;
(2) Install or modify arbitrarily;
(3) Incorrect operation or use;
(4) Do not depending on the manual to do cleaning or maintenance;
(5) Abnormal environment condition exceed the specifications, result in damage;
(6) The deliberate destruction of man-made;
(7) Irresistible natural disasters.
(Click The Picture, You can get more info)
Contact Info:
Junying li
Jinan Deming Power Equipment Co., Ltd
Tel: 0086 531 85662275 Fax: 0086 531 85662088 Mobile/WhatsApp: 0086 13287779981
Website: www.demingpower.cn www.demingpower.en.alibaba.com
Wechat: 13287779981 QQ: 351998931 Skype: demingpower2
E-mail: junyingli(at)demingpower.com.cn