Model | OPIP-1K-1 | OPIP-1K-1 | OPIP-1K-1 | OPIP-1K-2 | OPIP-1K-2 | OPIP-1K-2 | |||||
Rated power | 1000W | ||||||||||
Peak power | 2000W | ||||||||||
Input voltage | DC12V | DC24V | DC48V | DC12V | DC24V | DC48V | |||||
Output voltage | 100VAC or 110VAC or 120VAC±5% | 220VAC or 230VAC or 240VAC±5% | |||||||||
Unload current less than | 0.8A | 0.5A | 0.3A | 0.8A | 0.5A | 0.3A | |||||
Output frequency | 50Hz±0.5Hz or 60Hz±0.5Hz | ||||||||||
Output waveform | Pure Sine Wave | ||||||||||
Waveform distortion | THD<3%(Linear load) | ||||||||||
USB port | 5V 1A | ||||||||||
Max.efficiency | 90% | ||||||||||
Input voltage range | 10-15.5V | 20-31V | 40-61V | 10-15.5V | 20-31V | 40-61V | |||||
Low voltage alarm | 10.5±0.5V | 21±0.5V | 42±1V | 10.5±0.5V | 21±0.5V | 42±1V | |||||
Low voltage protection | 10±0.5V | 20±0.5V | 40±15V | 10±0.5V | 20±0.5V | 40±15V | |||||
Over voltage protection | 15.5±0.5V | 31±0.5V | 61±1V | 15.5±0.5V | 31±0.5V | 61±1V | |||||
Low voltage recover | 13±0.5V | 24±0.5V | 48±1V | 13±0.5V | 24±0.5V | 48±1V | |||||
Over voltage recover | 14.8V±0.5V | 29.5V±0.5V | 59V±1V | 14.8V±0.5V | 29.5V±0.5V | 59V±1V | |||||
Protection function | Low voltage | Alarm at first, voltage continously reduce. LED Red light on & shut sown. | |||||||||
Over voltage | LED Red light on, shut down | ||||||||||
Over load | LED Red light on, shut down | ||||||||||
Over temperature | Alarm at first, tempurature continously rise.LED Red light on & shut sown | ||||||||||
Short circuit | LED Red light on | ||||||||||
Input reverse polarity | Fuse burn-out | ||||||||||
Working temperature | -10°- +50° | ||||||||||
Storage temperature | -30°- +70° | ||||||||||
Dimension(mm) | 310x165x90mm | ||||||||||
Packing(mm) | 330x215x105mm | ||||||||||
Net./gross weight(g) | 2820/3260g | ||||||||||
QTY/Ctn | 6 Pcs | ||||||||||
Meas./Ctn(mm) | 440x350x330mm | ||||||||||
Gross weight/Ctn(g) | 3260g | ||||||||||
Warranty | 1 years | ||||||||||
Configuration | Standard | ||||||||||
Cooling method | Intelligent air cooling |