Model | Power & Size | Input | Output Voltage | Output Current |
GA-ICH060-CC1300A | 50W 143*46*33mm | AC 100-277V | DC 30-56V | 700-1300mA |
GA-ICH060-CC800A | DC 54-90V | 450-800mA | ||
GA-ICH100-CC2500A | 100W 164*53*33mm | DC 30-56V | 1200-2500mA | |
GA-ICH100-CC1500A | DC 54-90V | 800-1500mA | ||
GA-ICH150-CC3700A | 150W 186*60*38mm | DC 30-56V | 1900-3700mA | |
GA-ICH150-CC2300A | DC 54-90V | 1200-2300mA | ||
GA-ICH200-CC5000A | 200W 213*68*38mm | DC 30-56V | 2700-5000mA | |
GA-ICH200-CC3000A | DC 54-90V | 1600-3000mA | ||
GA-ICH240-CC6000A | 240W 230*68*38mm | DC 30-56V | 3300-6000mA | |
GA-ICH240-CC3500A | DC 54-90V | 2000-3500mA |
Item | |||||||
Voltage Range | AC 100-277V | ||||||
Limited Voltage | 277V AC | ||||||
Power Factor | >0.97 | ||||||
T.H.D | <10% | ||||||
Efficiency | 90% | ||||||
Output | Current Accuracy | ±3% | |||||
Power-on Time | <500ms | ||||||
Protection | Short Circuit | constant voltage mode, recover automatically after fault condition is removed | |||||
Over Loading | ≤120% constant voltage limiting, recover automatically after fault condition is removed | ||||||
Over Temperature | 100℃±10℃ Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
Others | Ta | 50℃ | |||||
Tc | 90℃ | ||||||
IP rating | IP67 | ||||||
Life span | 50000hours | ||||||
Warranty | 5years | ||||||
Notes | 1. All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation . 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |