Brief introduction (CHP3000 series online ups):
CHP3000 series online ups power supply system (3 phase input & 3 phase output) double conversion online ups with an isolation transformer at Output. The Load is supplied continuously by the inverter with clean, stabilized and regulated sine wave output power. Input & Output filters increase the immunity of load from power disturbances and surges.
CHP3000 series online ups adopts high-speed microprocessor (MCU), Programmable logic device(CPLD) program which are controlled by software, the sixth generation low exhaust and big power IGBT and static switch as power components. It entirely breaks through the technical bottleneck in traditional simulation age. It adopts the digital control technology and high-accuracy SMD technology.
CHP3000 series online ups can be widely used in telecom, bank, security, transportation, utility, manufacture, industry, commerce, medical equipments etc.
Capacity (CHP3000 series online ups):
10kva-800kva online ups
8kw-640kw online ups
Main Features (CHP3000 series online ups):
l True On line-Double Conversion Technology.
l 7 inches LCD+LED Big Screen Display.
l Stable Rectifier and Harmonic Filters.
l IGBT PWM Inverter Technology.
l High Efficiency up to 92%.
l Wide Input Voltage Range.
l Advanced Battery Management.
l Short Circuit and Overload Protection.
l 256 Real Time Event Log with Detailed Parameters.
l Static & Manual Bypass Operation.
l Advanced Communication Capabilities.
l Perfect Generator Compatibility.
l Cold Start Function.
l Auto Restart Function.
l Can Set ECO Work Mode.
l Optional EPO Function.
l True On line-Double Conversion Technology.
l 7 inches LCD+LED Big Screen Display.
Capacity(KVA) | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Power Watt(KW) | 8 | 12 | 16 | 20 | 24 | 32 | 40 | 48 | 64 | 80 | 96 | 128 | 160 | 200 | 240 | 320 | 400 | 480 |
Working Principle |
Low Freuqency Transformer Based True On Line-Double Conversion |
|||||||||||||||||
RECTIFIER (INPUT) | ||||||||||||||||||
Phase | Three Phase | |||||||||||||||||
Input Power Factor |
Standard more than 0.9 ( 6pulse Rectifier+Filter ), Optional more than 0.96 ( 12pulse Rectifier+Filter) |
|||||||||||||||||
Input Voltage Range |
220/380VAC (230V/400VAC or 240V/415VAC)±25% 3P+N+PE ; 110V/208VAC( 120V/220VAC or 277V/480VAC ) optional |
|||||||||||||||||
Input Frequency Range |
50Hz±10% / 60Hz±10% (Selectable) | |||||||||||||||||
Total Harmonic Distortion (THDi) |
6pulse Rectifier<30%, Optional 12pulse Rectifier & Filter<5% |
|||||||||||||||||
Output Ripple | <2% | |||||||||||||||||
Soft Start | 0~100% 5sec | |||||||||||||||||
CHARGING | ||||||||||||||||||
Charging Mode |
Constant current, then constant voltage, charge with temperature compensation, automatic switch Between Equalized charging and Float charging, |
|||||||||||||||||
Float Charging Voltage |
432VDC | |||||||||||||||||
Equalized Charging Voltage |
464VDC | |||||||||||||||||
Temp. Compensated Voltage |
-3mV/℃/cell | |||||||||||||||||
Charging Current | 0.1C ( Automatic adjust according to battery capacity) | |||||||||||||||||
BATTERY | ||||||||||||||||||
Type | VRLA/AGM/Gel, optional Lithium Battery | |||||||||||||||||
Battery Capacity |
7~999AH settable (Configurate Battery Capacity according to Back-up Time) |
|||||||||||||||||
Quantity |
32units 12V or 192units 2V batteries (Nominal Voltage 384VDC) |
|||||||||||||||||
Temperature | 20ºC~25ºC (For Maximum Efficiency) | |||||||||||||||||
INVERTER (OUTPUT) | ||||||||||||||||||
Phase | Three Phase | |||||||||||||||||
Rated Voltage | Rated Capacity*0.9 | |||||||||||||||||
Nominal Voltage |
220/380VAC (230V/400VAC or 240V/415VAC), 3P+N 110V/208VAC( 120V/220VAC or 277V/480VAC ) optional |
|||||||||||||||||
Output Voltage Regulated Accuracy |
±1%( Stable load), ±3%( fluctuant load) | |||||||||||||||||
Output Frequency Range |
50Hz 60Hz<±0.5% ( Asynchronous ) | |||||||||||||||||
Crest Factor | > 3:1 | |||||||||||||||||
Output Total Harmonic Distortion (THDi) |
Pure Sine Wave, Linear Load< 3%, Non-Linear Load<5% |
|||||||||||||||||
Dynamic Characteristics |
Instant voltage<±5% ( from 0 to100% ), Instant recover time<10ms |
|||||||||||||||||
Unbalanced Load Voltage |
< ±5% | |||||||||||||||||
Overload Capacity |
At 115% load, normal work, At 125% load 10 min, At 150% load 1min, At 200% load 1S |
|||||||||||||||||
Inverter Efficiency |
>92% ( full load ) |
>93% ( full load ) |
>95% ( full load ) | |||||||||||||||
BYPASS | ||||||||||||||||||
Phase | 3 Phase +N | |||||||||||||||||
Input Nominal Voltage |
220/380VAC (230V/400VAC or 240V/415VAC) 110V/208VAC( 120V/220VAC or 277V/480VAC ) optional |
|||||||||||||||||
Output Nominal Voltage |
220/380VAC (230V/400VAC or 240V/415VAC) 110V/208VAC( 120V/220VAC or 277V/480VAC ) optional |
|||||||||||||||||
Transfer Time | 0ms( adopt static switch ) | |||||||||||||||||
PROTECTION FUNCTION | ||||||||||||||||||
Input Protection |
Input voltage, frequency over limited protection, Phase fault, Phase lack |
|||||||||||||||||
Output Protection |
Over current, short circuit, over voltage, low voltage |
|||||||||||||||||
Battery Protection |
Over charge, over-discharge protection |
|||||||||||||||||
Temperature Protection |
Environment over temperature protection, inverter over temperature protection |
|||||||||||||||||
Hardware Fault Protection |
Assistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc protection |
|||||||||||||||||
GENERAL SYSTEM PARAMETERS | ||||||||||||||||||
Working Environment |
Temp: -10~40ºC, relative humidity: 30%~90%, Altitude<2000m ( 1% decrease against 100 meters’ rise, max. altitude 4000m ) |
|||||||||||||||||
Cooling Method |
COMPULSIVE VENTILATION | |||||||||||||||||
Communitation Interface |
RS232/ RS485, optional dry contact, SNMP card ( for remote control via Internet) |
|||||||||||||||||
Parallel Operation |
Tandem hot backup or parallel connection | |||||||||||||||||
Auti-surge Capacity |
10/700μS, 5KV; 8/20μS, 20KA | |||||||||||||||||
Protection Level |
IP31 | IP30 | ||||||||||||||||
Safety Performance |
Vin-n Vout-n 3000Vac, creepage<3.5mA , insulating resistance>2MΩ(500VDC) |
|||||||||||||||||
Noise (dB) | 48~55 | 55~60 | 60~65 | 65~70 |
FAQ
Q: Why choose us?
A: We are China Leading ups&solar system Manufacturer, 14 years experience in producing and marketing
ups & solar products.
100% QC inspection Before Shipment.
Best Quality & Best Service with Competitive price.
Good after-sale service: 2 years warranty and if possible we provide on-site installation and repairing
All of our products have the CE certificate, ISO9001,ISO14001,OHSAS18000,TLC, IEC authentication, and Chinese energy conservation certification
Market covers the 100 cities and countries all over the world. Have branch office in Pakistan, Australia, etc.
If you have some problems about CHP series online ups , or want to know more details about 3 phase ups,3 phase ups system,480 volt 3 phase ups,apc 3 phase ups,3 phase ups circuit,lithium battery, solar inverter,etc. Welcome to contact us!
Looking forward to your inquiry in alibaba.