100L / 200L / 300L lab autoclave retort
The steam water spray type sterilizing retort heats the water of the hot water tank to a predetermined temperature by directly injecting steam, and then injects into the process tank, and continuously circulates the process water in the pot, and sterilizes by circulating steam heating. Mingo automatic water steam spray batch retort thereby shorten the sterilization time and improve work efficiency. The sterilized process water can be recycled, saving energy, time and manpower, material consumption, and reducing production costs.
spray method
1. Soft package: Aluminum foil bag, transparent bag, vacuum bag, retort pouches, ect.
2. Plastic Container: PP bottle, HDPE bottle, plastic bowl, ham sausage, pure milk
1. high temperature short time sterilization,A small amount of process water cycles rapidly to reach the per-set sterilization temperature,because of dispensing with exhausting before heating up,so up to 30% less needs in energy compared with traditional steam retort;
2. sterilization temperature and pressure control independently to meet the product is wide, save investment;
3.indirect cooling, cooling water doesn’t contact with process water to avoid the secondary pollution of food,no need of treatment for cooling water;
4.PLC fullautomatic control is used for entire sterilization process which controls the heat distribution temperature within ±0.5℃;It can set multistage heating to save energy;It has F value measuring function and can store 100 sterilization formula;
5. Process water preheating system guarantees the hot filling product get continuous heating process;
6. Steam for sterilization function is optional;automatic up-sliding door and side-sliding door for option;
7.The whole sterilization process autocompletes in strict accordance with preset technical formula which has multilevel password to eliminate the possibilities of misoperation;
8. After power recovery, procedure will automatically recover to the preceding state before power failure;
9. Retort door is equipment with triple interlocking device to prevent the misoperations and accidents efficiently;
10.Double safety valves and pressure sensors are adopted to eliminate potential safety hazard.
Pro. No. | Dia (mm) | Length (mm) | Width (mm) | Height (mm) | Volume(m³) | Steam | Power(KW) | Design temperature (℃) | Design pressure (Mpa) |
MGR-D0.7-1.85 | 700 | 1850 | 1200 | 1800 | 0.28 | 15 | 2.1 | 147 | 0.35 |
MGR-D0.9-2.2 | 900 | 2200 | 1700 | 2100 | 0.56 | 25 | 4 | 147 | 0.35 |
WE ALWAYS EXPLOR ALL THE POSSIBILITIES TO HELP CUSTOMERS TO SOLVE PROBLEMS AND UPGRADE THEIR PRODUCTS QUALITY.
1. What if there is something wrong with the machine within one and half year?
We have two ways to solve this problem:
1).Phone call guidance to confirm the problem.
2). We will take video to show 'how to solve the problem'. All the problem can be solved by video guidance.
2.What if the PLC is suddenly broken down?
If really broken down, what we usually do is:
1) We suggest customer to buy one more for storage. The computer we will also upload the program.
2) Once it is broken down, then take replace the new one, the broken one, send back to us, we re-do the system, and send it back to you again.
3.What is the difference between retort and autoclaving?
Both words refer to the process of sterilizing a given item. This item could be medical instruments, a sealed container of food, or anything else.So there is no difference between these two terms. They are two different ways to say the same thing.
4.Is retort machine advisable to replace autoclave in microbiology laboratory?
A retort is an autoclave. The difference here is that our retorts can perform various processes i.e. water spray, water immersion and steam-air in addition to saturated steam with or without horizontal or rotational agitation.