Enquiries
Message
Home > Products > Other
1-1/2" tri-clamp with cooling element flush diaphragm pressure sensor/transducer/transmitter
  • 1-1/2" tri-clamp with cooling element flush diaphragm pressure sensor/transducer/transmitter

1-1/2" tri-clamp with cooling element flush diaphragm pressure sensor/transducer/transmitter

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Shaanxi, China
Brand Name:
VOLLTEL
Model Number:
PM310
Pressure range:
-1~0bar,0~0.1bar,...,100bar
Output signal:
4~20mA,0~10VDC,0~5VDC,1~5VDC,0.5~4.5V
Accuracy:
0.1%FS,0.25%FS,0.5%FS
Power supply:
24VDC,12~36VDC,9VDC,5VDC
Pressure connections:
2 inch clamp,G1/2,1/2NPT,PT1/2,1/2BSP,M20*1.5,others
Electrical connections:
Connector DIN43650, M12x1 connector 4-pin, Cable outlet with cable
Protection:
IP65, IP66, IP68
Operating Temp. Range:
-20 to +85°C
Material of Diaphragm:
316L stainless steel, Option Hastelloy C
Certificate:
CE, ISO9001
Supply Ability
Supply Ability:
5000 Piece/Pieces per Month 1-1/2" tri-clamp with cooling element flush diaphragm pressure s
Packaging & Delivery
Product Description

1-1/2" tri-clamp with cooling element flush diaphragm pressure sensor/transducer/transmitter

Product Overview

PM310 is made from high-quality silicon Piezoresistive chip. All process connections of the flush pressure

transmitter are made of stainless steel, fully welded and isolate the process medium from the pressure measuring instrument via a positive seal. The PM310 is precision engineered to fit food, pharmaceutical and chemical liquid pressure measurement.

A wide range of process connection and electrical connection options are available to meet almost requirement.

Features

- Pressure measuring ranges from 1bar to 100bar

- Absolute, gauge and sealed gauge                                

- Accuracy: ±0.5%FSO

- Calibrated and temperature compensated

- Flush diaphragm construction

- Piezoresistive pressure sensor design

- Variety of Pressure & Electrical connections

- Output 4...20mA,0...10V,0...5V and others

 stainless steel case IP68 diaphragm pressure transmitter in high-humidity environments Applications

- Process control systems

- Food and beverage

- Medical

- Papermaking

- Dairy

Product details of PM300-Flush Diaphragm pressure transmitter for Food and Beverage Industry

 

Performance Specifications

 

Parameter

Value

Units

General

Pressure Range

0-0.1,...,100

bar

Overpressure

1.5xFS

bar

Environmental

Operating Temp.Range

-20 to +80

°C

Compensated Temp.Range

0 to 50

°C

Vibration

10

g(20 to 2000Hz)

Shock

100

g(10ms)

Cycles

10x106

cycles

Electrical @25°C(77°F)

Output Signal

/Supply Voltage

4...20 mA: 24 (12...36) VDC

0...5 VDC: 24 (12...36) VDC

1...5 VDC: 24 (12...36) VDC

0...10 VDC: 24 (15...36) VDC

0.5...4.5 VDC: 5 VDC (ratiometric)

 

Load Resistance

<(Vs-12)/0.02A (For current output)

>10kΩ (For voltage output)

 

Insulation Resistance

100

MΩ@50VDC

Physical Specifications

Media Compatibility

All media compatible with 316L SS

 

Housing

304 stainless steel

 

Diaphragm

316L stainless steel

 

Seal Ring

Viton or NBR

 

Oil Filling

Silicone oil

 

Protection

IP65,IP67

 

Net Weight

Approx.295g

 

Performance1

Accuracy2

±0.5[typ.]

% FSO

Temp. Coeff– Zero3

±1.5[typ.]

% FSO

Temp. Coeff– Span3

±1.5[typ.]

% FSO

Long-Term Stability

±0.3[typ.]

% FSO

Notes

1. All values measured at 25°C(77°F)

2. Including non-linearity, hysteresis and repeatability.

3. 0°C to 50°C(32°F to122°F) with reference to 25°C(77°F).

The listed specifications and dimensions are subject to change without prior notice.

 

 

1-1/2" tri-clamp with cooling element flush diaphragm pressure sensor/transducer/transmitter Dimensions in mm

 

 Connection Diagrams

 

Product testing diagram

 

Mounting location

Ordering Information

Note: Please contact us for product Datasheet

Model / Measuring range / Output signal / Supply Voltage / Electrical connection / Process connection

Correct specification examples: PM20S - 0~10barG - 4~20mA - 24VDC - DIN43650 - G1/4 male

 

Packaging & Shipping

Our Services

 

 

 

Custom Sensors: Four Steps to Get Your Custom Sensor

1. Concept

We will work closely with you to analyze your measurement task and design the matching solution. Through rapid engineering (CAD) you get first concepts for your transducer in a short time. Advice on conceptual design is free for you.

2. Quote

After having agreed the concept with you, we provide you with a quote for the customized transducer that really meets your unique requirements.

3. Prototype

Get a prototype of your sensors in a short time... Rapid prototyping makes it possible.

4. Production

If the prototype meets your requirements, production starts. Benefit from the proven quality and delivery reliability of the leading manufacturer with decades of experience.

 

Calibration services

 

Repair Services

Rush repairs are turned around in little as 48-72 hours whether it's a standard or custom design.

Non-rush repairs are returned to you in 10 working days.

 

Company Information

 

 

FAQ

Can you provide calibration report of flush diaphragm pressure sensor  ?

Yes, VOLLTEL can provide calibration report.

Can you accept OEM brand?

Yes, VOLLTEL can accept OEM brand without extra charge.

Can you offer sample for flush diaphragm pressure sensor?                                                         

Yes, you can apply for sample testing.

Warranty=?

12 months (option 18 months)

How long will you give me the reply?

we will contact you in 12 hours as soon as we can.

What pressure range should I work in?
A gauge range of twice the working pressure is generally selected. The working pressure in all cases should be limited to 75% of the gauge range. Where alternative pressure and pulsation are encountered, working pressure should be limited to 2/3 of the gauge range

What do I need to know to select the right product?
The following are the basics for most products used in industrial environments: Application - Pressure range - Temperature range - Medium - Pressure Connection

 

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher