1 1/2 inch lpg 12v solenoid valve for boiler
Introduction of the production
Fuel gas solenoid valves are widely applied to the safe transportation of fuel gases so as to start the supply of gases or cut it off upon emergency.
The mediums of gases applicable are: natural gases, methane, liquefied petroleum gas.
When activated, the blue indicator lights up, this allows the operators to check working mode through visual observation.
Operation and installation
Normally closed type, after the power is on, it will open quickly, and when the power is off, it will be closed immediately.
By-pass ports are set on both sides and bottom of the valves, with diameter of G1/4” (DN10/15 diameter being G1/8”)
Technical features
Opening Time: less than 1 second
Closing Time: less than 1 second
Numbers of operations: 20 per minute.
DN10-25 360mbar:DN32-50 200mbar
Max working Pressure: 200/360mbar
By-pass ports are set on both sides of the valves,
with diameter of G1/4”
Built-in filter
Protection: IP54
Sealing material: chemigum
Body material: aluminum alloy
Pressure steel spring AISI 302.
The ambient temperature: -15℃- 60℃
Coil temperature: 65℃
Standard and certificate
achieving Grade A standard
Meet EN161 standard
Meet European Gas Standards
CE Certification
Electrical specification
Voltage: 50-60Hz, 230Vac,110Vac,24Vdc (other voltage can be customized).
Coils to Class F, can be 360° rotation, can work 100% continuously for a long time.
Model | Passage DN (mm) | Connection | Max Pressure (Mbar) | Operating temperature(℃) | Protection |
LCV-MG10S | 10 | RP 3/8" | 360 | -15 to 60 | IP54 |
LCV-MG15S | 15 | RP 1/2" | 360 | -15 to 60 | IP54 |
LCV-MG20S | 20 | RP 3/4″ | 360 | -15 to 60 | IP54 |
LCV-MG25S | 25 | RP 1″ | 360 | -15 to 60 | IP54 |
LCV-MG32S | 32 | RP 1¼″ | 200 | -15 to 60 | IP54 |
LCV-MG40S | 40 | RP 1½″ | 200 | -15 to 60 | IP54 |
LCV-MG50S | 50 | RP 2" | 200 | -15 to 60 | IP54 |
LCV-MG65S | 65 | PN 16 1½" | 200 | -15 to 60 | IP54 |
LCV-MG80S | 80 | PN 16 3" | 200 | -15 to 60 | IP54 |
LCV-MG100S | 100 | PN 16 4" | 200 | -15 to 60 | IP54 |
Model | Length L(mm) | Width W(mm) | Height (closed/open) H(mm) | Coil radius of gyration S(mm)
|
LCV-MG10S | 72 | 71 | 160/165 | 55 |
LCV-MG15S | 72 | 71 | 160/165 | 55 |
LCV-MG20S | 92 | 75 | 173/179 | 55 |
LCV-MG25S | 100 | 80 | 179/181 | 55 |
LCV-MG32S | 149 | 115 | 222/234 | 55 |
LCV-MG40S | 149 | 115 | 222/234 | 55 |
LCV-MG50S | 170 | 142 | 237/249 | 55 |
Model | Length L(mm) | Width W(mm) | Height (close/open) H(mm) | Coil radius of gyration S(mm) | Flanged size (mm) | |||
D | K | L1 | N | |||||
LCV-MG65S | 310 | 185 | 303/316 | 59 | 185 | 145 | 18 | 4 |
LCV-MG80S | 310 | 200 | 312/325 | 59 | 200 | 160 | 18 | 8 |
LCV-MG100S | 348 | 250 | 369/392 | 70 | 220 | 180 | 18 | 8 |
LCV-MG Series installation dimension
Our Factory