FFC cables meet and often exceed ROHS electrical performance and mechanical performance, with high voltage 3500V, insulation voltage 500V, tensile force 20N (0.5mm pitch) and 30N (1.0mm pitch), and bending for 10,000 times. Retention force ≥ 3.5kg; repeated insertion/withdrawal ≤ 50mΩ; insulation elongation ≥ 60%; insulation tensile strength≥34.3N/m m2; the three functional tests of dielectric strength, flexing test and flame test are all OK; contact resistance≤0.03Ω; insulation resistance≥ 100MΩ; characteristic resistance: 100MΩ±10%; no short circuit, open circuit, dislocation;
FFC Attributes & Parameters |
|||||
Items |
FFC Assembly Basic Attribute |
FFC Assembly Parameter |
|||
ID |
Model No. |
Y20071704 |
|||
Flat Wire |
Conductor |
Materials |
Bare copper |
||
Conductor gauge |
Ct*Cw=0.035*0.3 Thickness*Width=0.035*0.3 |
||||
Resistance (Ω) |
<2.2Ω/m |
||||
Freeze frame voltage (V) |
60V |
||||
Pitch (p) |
0.5PH |
||||
Pin Number |
80Pin |
||||
Electroplating |
Electroplating material |
matte gold-plated |
|||
Span (Pt) |
39.5mm |
||||
Margin (M) |
0.5mm |
||||
Flammability standard |
UL sub.758 VW-1 |
||||
PET Film |
Materials |
Polyester |
|||
Thickness |
0.06mm |
||||
Printed (can be customized) |
Beautiful E362551 AWM 20861 105℃ 60V VW-1 |
||||
Absorbing material |
Materials |
Polymer-based |
|||
conductive cloth |
no |
||||
Acetate cloth |
no |
||||
Damping cotton |
no |
||||
Sound-absorbing cotton |
no |
||||
Resistance temperature film |
no |
||||
Foam glue |
no |
||||
Connector |
Connector Basic Attribute |
Connector A Parameter |
Connector B Parameter |
||
Connector brand |
Qiao Yu |
|
|||
Support tape |
Materials |
Polyester |
|
||
Length |
5mm |
|
|||
Thickness |
0.225mm |
|
|||
Items |
FFC Integrated Attribute |
FFC Parameter |
|||
Mechanical performance |
Stripping strength |
The puller conducts a stripping test at a speed of 25+/-3mm/min |
|||
Insertion force |
20gf-Min |
||||
Withdrawal force |
20gf-Min |
||||
Repeated insertion/withdrawal |
Insert and withdraw 20 times with suitable FFC connector at a speed of 10 times/min without damage to the appearance |
||||
Flame retardance |
VM-1 pass |
||||
Bending test |
100000 times (back and forth distance 10mm, 180 times/min) |
||||
Flexibility |
Flexible type |
Small volume, high precision, good flexibility, better weldability, and easy to bend |
|||
Aging |
Up to 60℃ at a speed of 22℃/min; down to the normal temperature at a speed of 2°C/min and maintain 96 h |
||||
winding resistant |
100000 times (back and forth distance 10mm, 180 times/min) |
||||
Abrasion-resistant |
Travel 100mm at 60 times/min with a load of 600±5g and conduct abrasion test 10000 times without damage to the appearance. |
||||
Bending |
Travel 100mm at 60 times/min with a load of 600±5g and conduct abrasion test 10000 times without damage to the appearance. |
||||
Electrical performance |
On resistance |
DC3V,0.1mA, no short or open circuit |
|||
Contact resistance |
0.38MΩ |
||||
Insulation resistance |
Apply DC 500V to measure the neighboring conductors or between the conductor and the ground. The resistance shall be more than 1000MΩ. |
||||
Rated voltage |
Apply AC 500V, 5mA to measure the neighboring conductors or between the conductor and the ground for one minute and there is no breakdown. |
||||
Rated current |
Current capacity≥0.5A |
||||
Dielectric strength |
Increase the voltage to 1500V gradually in 10s and maintain 1 min. Then decrease the voltage to 750V in 10s. No flash line or breakdown. |
||||
Environmental adaptability |
Salt spray test |
Test time: 48H; saltwater concentration: 5% pressure barrel temperature 35±5℃; pressure barrel pressure: 3kg |
|||
Moisture resistance |
Place in the air at 40±2℃ and relative humidity 90-95% for 96 hours, and then return to room temperature for 0.5-2 hours to measure |
||||
Cold resistance |
Place in the air at -40±2℃ for 96 hours, then return to room temperature for 0.5-2 hours |
||||
Heat-resistance |
Place in the air at 80±2℃ for 96 hours, then return to room temperature for 0.5-2 hours. No damage to the appearance |
||||
Temperature cycling |
40℃→+25℃→85°C→+25℃ x 5 Cycle 40℃:4H / 25℃:0.5H / 85℃:8H |
||||
Storage environment |
15°C~25°C |
FFC cable production is fully automatic, with high precision and strong inspection.
The production flow is as follows:
FFC cables are widely used in the following applications: digital cameras, graphic plotter, digital camcorders, laptops, LCD TVs, LCD monitors, DVD player, stereo, audio system and computer module, etc.