Product Name | 0.75kw-315kw Universal Frequency Inverter Vector Speed Controller For Industry Motor |
Model | G5OO-110G132P-4T |
Brand | CRAFTSMAN |
Color | White |
Basic information | Power:110/132kw Style:Three phase Rated voltage:380V-480V Rated frequency:50Hz-60Hz |
Function description | Maximum Frequency:0~600Hz,0~3000Hz Can be customized according to the requirement |
Carrier Frequency:1.0Khz~16.0Khz Carrier frequency can be automatically adjusted | |
Input Frequency Resolution: Digital setting:0.01hz Analog setting:0.1Hz | |
Control Mode:No speed sensor vector control, no speed sensor vector control 1, V/F control, torque control | |
Application:Widely used in machine tool industry,electric power industry,chemical industry,textile industry and so on. |
Item | Specification | ||||
The basic function | The highest frequency | 0~600Hz,0~3000Hz can be customized according to customer demand. | |||
Carrier frequency | 1.0KHz~16.0KHz,carrier frequency can be automatically adjusted. | ||||
Input frequency resolution | Digital setting:0.01Hz;Simulation setting:0.1Hz. | ||||
The control mode | No speed senor vector control,no speed sensor vector control 1,V/F control,Torque control. | ||||
Starting torque | 0.5Hz/150% | ||||
Overload capacity | Model G:rated current of 150% for 60 seconds;180% rated current 10 seconds.Model P:120% rated current for 60 seconds;150% rated current 10 seconds. | ||||
Torque increase | Automatic torque lifting; Manual torque increased by 0.1%~30.0% | ||||
Acceleration deceleration curve | Straight line or S-curve acceleration and deceleration mode.The four acceleration and deceleration time ranges from 0.0 to 3600.0s. | ||||
DC brake | DC braking frequency:0.00Hz~ maximum frequency,braking time:0.0s~50.0s,braking action current value:0.0%~120.0%. | ||||
Inching control | Inching frequency range:0.00Hz~50.00Hz.The inching acceleration time is 0.0s~3600.0s. | ||||
Simple PLC,mult-speed operation | Through the built-in PLC or control terminal to achieve up to 16 segments of operation. | ||||
Built-in PID | The closed loop control system of process control can be conveniently realized . | ||||
Automatic voltage regulation(AVR) | When the network voltage changes,the output voltage can be maintained constant automatically. | ||||
Fast current limiting function | Minimize overcurrent failures and protect the normal operation of the converter. | ||||
Dynamic over-voltage suppression | When the operating frequency changes,the energy feedback is automatically suppressed to prevent bus over-voltage tripping. | ||||
Oscillation suppression | Optimize VF oscillation suppression algorithm to realize VF stable operation. | ||||
Non-stop instantaneous power failure | The instantaneous power failure through the load feedback energy compensation voltage reduced,Maintain the inverter in a short period of time to continue running. | ||||
V/F individual control | Individually adjustable voltage and frequency preset. | ||||
Motor switch | Two groups of motor parameters,Two motor switching control can be achieved. | ||||
Support multithreading bus | Support for multiple field bus:Modbus,Profibus-DP,CANopen | ||||
Fan control | Fan operation can be controlled to increase fan life. | ||||
Running command channel | Three types of channels:operation panel reference,control terminal reference and serial communication port reference;These channels can be switched in various modes | ||||
Frequency source | There are nine types of frequency sources,such as digital reference,analog voltage reference,analog current reference,pulse reference,PLC,MS speed,PID,and serial port reference,potentiometer reference. | ||||
Auxiliary frequency source | There are nine types of auxiliary frequency sources,Flexible realization of auxiliary frequency tuning and frequency synthesis. | ||||
Input terminal | Standard:There are eight digital input terminals,one of which can be used as high-speed pulse input;There are two analog input terminals, with optional 0~10V input voltage or 0/4~20mA current input; | ||||
Output terminal | Standard:Two analog output terminals,with optional 0~10V input voltage or 0/4~ 20mA current output;Two digital output terminals,one of which support 0~50KHz square wave signal high-speed pulse output,two relay output terminal. | ||||
LED display | Display parameter | ||||
Parameter copy | Can upload or download function code information of inverter to realize fast parameter copy. | ||||
Key lock and selection function | Achieve some or all of the keys locked, scope definition part of the keys to prevent misuse | ||||
Fault alarm | Over-voltage,under-voltage,over-current,short circuit,open phase,overload,overheat,over-voltage speed lost,current limit,etc. | ||||
Using place | Indoor,and be free from direct sunlight,dust,corrosive gas,combustible gas, oil smoke,vapor,drip or salt. | ||||
Altitude | 1000M, derated when above 1000M | ||||
Ambient temperature | -10℃ Celsius to +40℃ Celsius(Derated when used in the ambient temperature of 40℃ Celsius to 50 ℃ Celsius) | ||||
Humidity | Less than 95% RH,without condensing | ||||
Vibration | Less than 5.9m/s2(0.6g) | ||||
Storage temperature | -20 Celsius to +60 Celsius |